Part Number |
Inductance(uH) |
Testing Freq(MHz) |
RDC(A)Max |
SRF(MHz)Max |
DRS0804-1R0M |
1.0  20% |
0.009 |
9.0 |
100 |
DRS0804-1R5M |
1.5  20% |
0.010 |
8..0 |
90 |
DRS0402-2R2M |
2.2  20% |
0.012 |
7.0 |
80 |
DRS0804-3R3M |
3.3  20% |
0.015 |
6.4 |
65 |
DRS0804-4R7M |
4.7  20% |
0.018 |
5.4 |
45 |
DRS0804-6R8M |
6.8  20% |
0.027 |
4.6 |
38 |
DRS0804-100M |
10.0  20% |
0.038 |
3.8 |
30 |
DRS0804-150M |
15.0  20% |
0.046 |
3.0 |
27 |
DRS0804-220M |
22.0  20% |
0.085 |
2.6 |
19 |
DRS0804-330M |
33.0  20% |
0.100 |
2.0 |
15 |
DRS0804-470M |
47.0  20% |
0.140 |
1.6 |
12 |
DRS0804-680M |
68.0  20% |
0.200 |
1.4 |
10 |
DRS0804-101M |
100  20% |
0.280 |
1.2 |
9.0 |
DRS0804-151M |
150  20% |
0.400 |
1.0 |
6.0 |
DRS0804-221M |
220  20% |
0.610 |
0.8 |
5.0 |
DRS0804-331M |
330  20% |
1.020 |
0.6 |
4.5 |
DRS0804-471M |
470  20% |
1.270 |
0.5 |
3.5 |
DRS0804-681M |
680  20% |
2.020 |
0.4 |
2.5 |
DRS0804-102M |
1000  20% |
3.000 |
0.3 |
2.0 |
Other non standard inductance value are available to meet your exact requirements.
Note:
1.Inductance measured by LCR Meter HP 4294/HP4291
2.DCR measured by Milliohm meter CH502AC
|