HOME > Product Category > Inductor Manufacturer > Line Filters > UU Type > Electrical Characteristics of UU10

Part Number
Inductance
(uH)
Rated Voltage
(AC/DC)
Rated Current
(Amp.)
DC Resistance
Max.(mOHM)*
Test Voltage
(VAC)**
Insulation Resistance
Min.(M.OHM)***
Temperature
Rise Max.()
Temperature
Range ()
UU-10-103M-0.3A
1000020%
250V
0.3
3
2000
100
40
-25~120
UU-10-502M-0.3A
500020%
250V
0.3
2
2000
100
40
-25~120
UU-10-502M-0.5A
500020%
250V
0.5
1.5
2000
100
40
-25~120
UU-10-402M-0.7A
400020%
250V
0.7
1
2000
100
40
-25~120
UU-10-302M-1.0A
300020%
250V
1.0
0.5
2000
100
40
-25~120
UU-10-202M-1.0A
200020%
250V
1.0
0.5
2000
100
40
-25~120
UU-10-102M-1.3A
100020%
250V
1.3
0.4
2000
100
40
-25~120
UU-10-102M-1.3A
100020%
250V
1.3
0.3
2000
100
40
-25~120
UU-10-102M-1.5A
100020%
250V
1.5
0.2
2000
100
40
-25~120
UU-10-601M-2.0A
60020%
250V
2.0
0.2
2000
100
40
-25~120
* Line at one side(Mohm=milliohm)
** For one minute between lines
*** At 500V DC between lines (M.OHM=mega OHM)

Other non standard inductance value are available to meet your exact requirements.

Note:
1.L Tested by LCR Meter CH102 @1KHz
2.DCR measured by Milliohm meter CH502AC